Ad Code

SOP For Cleaning of Drains

Here you find Standard Operating Procedure of Cleaning of Drain, which is given below.

{getToc} $title={Table of Contents}

Objective:

To lay down the procedure for cleaning of drains.

Scope:  

This procedure is applicable to all departments having drains.

Responsibility

Microbiologist.

Accountability:

Quality Control Manager.

Procedure:

First of all, Flush the drains with lot of potable water. 

Prepare the disinfectant solution as per given below.

Pour 200ml of the following disinfectant solutions under use at the end of day’s work 
in all the drains and record the activity.

10% Formalin Solution

Quantity of disinfectant: 27ml  of (commercially available 37% formalin solution)

Quantity of Water: 73ml

Final Volume:100ml

Final Concentration:10%

Procedure: to make 10% formalin solution; Take 27ml of (commercially available 37% formalin solution) in 100ml sterilized measuring cylinder and add 73ml of distilled water to make up the final volume upto 100ml. 

5% Potassium Permanganate

Quantity of disinfectant: 5g

Quantity of Water: 100ml

Final Volume:100ml

Final Concentration: 5%