SOP For cleaning of sterile area microbiology lab is described in this post which you can follow in the section of the microbiological lab.
{getToc} $title={Table of Contents}
Objective:
This procedure has been established for cleaning of sterile area microbiology lab.
Scope:
This procedure is applicable to all microbiology lab.
Responsibility:
Microbiologist.
Microbiology lab attendant
Accountability:
Quality Control Manager.
Procedure:
Commonly used disinfectants for cleaning:
Disinfectant used
for cleaning of Microbiology lab |
||
Disinfectant Name |
Concentration |
Category |
IPA (Isopropyl
Alcohol) |
70% |
A |
Phenol |
5% |
A |
2.5% |
B |
|
H2O2 |
7% |
A |
3% |
B |
|
Gluteraldehyde |
3.5% |
A |
Combination
Disinfectants Category “C” |
||
Disinfectant Name
|
Concentration |
Ratio |
IPA+Phenol |
70%+2.5% |
1:1 |
IPA+ H2O2 |
70%+3% |
1:1 |
Phenol+ H2O2 |
2.5%+3% |
1:1 |
Start the cleaning process from Sterility room moving forward towards change rooms.
Always wipe and mop the surface in "S" shaped unidirectional form.
Freshly prepared disinfectant solutions must be used.
Always use distilled water if not available then purified water for preparing disinfectant solutions.
For moping surfaces always use sterilized lint free dusters.
Alternatively change disinfectant solution used for cleaning of sterile area microbiology lab on daily basis.
Record the preparation of disinfectant and cleaning of sterile area microbiology lab in their respective logbooks.
Frequency: Once in a day. at operational state and once in a week at rest.
{getButton} $text={Download in Microsoft Office} $icon={Download} $color={Hex Color}