Standard Operating Procedure of Operational Vibro Sifter in pharmaceuticals is describe in this post.
1.0 Purpose
1.1 To lay down the cleaning procedure for Vibro Sifter.
2.0 Scope
2.1 This SOP is applicable for Vibro sifter used in manufacturing area in Production department.
3.0 Responsibilities
3.1 Execution: Operator
3.2 Checking : Pharmacist Above
4.0 Definition And Abbreviations
4.1 IPA :Iso- Propyl Alcohol
4.2 SCP :Standard Cleaning Procedure
5.0 Material and Equipment
5.1 sieve and silicon
5.2 water
5.3 2.5% “Teepol
5.4 Isopropyl
6.0 Safety Consideration
NA
7.0 Procedure
7.1 Put “OFF” the electrical supply and cover motor, starter, plug and leads with polybags.
7.2 Remove hopper, sieve and silicon gasket and clean with 50 liter Portable water at least two times till all residue is washed off.
7.3 Clean with 2.5% “Teepol” solution by using lint free cloth and rinse with 50 liter Portable water thoroughly.
7.4 Apply 25 liter hot water to hopper and sieve & finally rinse with about 50 liter purified water.
7.5 Wipe out all the items with dry lint free clean cloth and then wipe out with 70% v/v solution of Isopropyl
7.6 Alcohol (IPA) and then keep on pallet.
7.7 Affix “Cleaned” label and fill the “Equipment Log Book”.
7.8 Re- cleaned if not used within 72 hours.1.0 Purpose